Current Setting on a Portable Charger: What Are the Six Steps For?
When people choose a portable charger they mostly look at power: how many kW? Yet in daily use the feature that really does the work usually sits somewhere else — being able to set, step by step, the current the unit will draw. Thanks to it the same unit works both on a household socket with a weak fuse and on a three-phase industrial socket. Below we have gathered what the steps mean, how many kW each one gives, and when you should step down.
What does current setting mean?
In AC charging it is not the car but the charger that decides how much current will be drawn. The unit keeps sending the car a signal saying "you may draw at most this many amps from this run", and the car obeys that ceiling. The current setting lets you change that ceiling. Lowering the power does not break charging, it only slows it down — and in most situations that is exactly the right thing to do.
How many kW do the six steps give?
On the Pro Mobile 2 the charging current is set in six steps: 6, 10, 16, 20, 25 and 32 amps. On a three-phase socket each step corresponds roughly to the following (it can move by a few hundred watts with the grid voltage):
| Step | Three-phase power | Typical use |
|---|---|---|
| 6 A | about 4.2 kW | Very weak run, long extension, shared socket |
| 10 A | about 6.9 kW | Older wiring, slow overnight charging |
| 16 A | about 11.1 kW | 5/16A industrial socket |
| 20 A | about 13.9 kW | Middle step, a safe ceiling on runs that warm up |
| 25 A | about 17.3 kW | When a 32A run is shared with other loads |
| 32 A | about 22.2 kW | 5/32A industrial socket, full power |
On a single-phase run the same current gives roughly one third of the power: 16 amps on a single phase makes 3.7 kW and 32 amps makes 7.4 kW. That is why Mini Mobile works between 2.3 – 3.7 kW with its two steps of 10A/16A, and Mono Mobile between 3.7 – 7.4 kW with its two steps of 16A/32A.
Why would you step down?
Stepping down is not a shortcoming, it is a tool. It is used most often in these situations:
- The wiring is weak or old: the cross-section and the fuse of the run cannot carry a high current continuously.
- The run is long: once an extension cable comes in, resistance rises, voltage drops and the cable heats up.
- The socket is shared: if a heater, an oven or workshop equipment sits on the same run, the total load can trip the fuse.
- Hotels, campsites, holiday resorts: when you do not know the capacity of someone else's installation, starting on a low step is the safest approach.
- Charging from solar: by limiting the current to match production you can reduce what you draw from the grid.
- The plug is getting warm: heat you can feel by hand is the clearest sign that the run cannot carry that current continuously.
Why would you step up?
The only reason to go up is time. Once you are on a suitable industrial socket, moving to the full step shortens charging noticeably; that is what lets one unit serve several vehicles from morning to evening in site, fleet and service use. But the ceiling is not only in the unit: the real limit is whichever is lower, the capacity of the run or the car's own AC charger. A car whose onboard charger is 11 kW takes 11 kW even on a 32 amp socket.
How do you choose the right step?
- Find out the fuse rating of the run that feeds the socket; the step must stay below that value.
- Check whether other loads sit on the same run; if they do, go one step further down.
- Start the first charge on a low step and check the plug and the cable by hand after half an hour.
- If there is no heating, move up one step and repeat the same check.
- If you need a permanent answer, think of a fixed unit rather than patching the run; a dedicated circuit is the safest route.
The relationship between the fuse and the step
Charging differs from the other loads in a house at one point: it lasts hours rather than minutes, and the current stays almost constant throughout. That is why the number written on the fuse is not the current that can be drawn continuously; choosing a step close to it makes the fuse trip over time. The practical rule is to stay one step below the fuse rating of the run — on a 16 amp run you pick the 10 amp step rather than 16.
How many steps does each Bemis model have?
| Model | Steps | How it is set |
|---|---|---|
| Mini Mobile | 10A / 16A | Two steps |
| Mono Mobile | 16A / 32A | Two steps |
| Pro Mobile 2 | 6 / 10 / 16 / 20 / 25 / 32 A | Mobile app or the button on the unit |
This is what makes the Pro Mobile 2 the flagship of the portable range: six steps make fine adjustment to the capacity of the run possible, and because the setting can also be made from the phone you do not have to walk over to the unit. So the same unit can run at 10 amps on a weak socket at home during the week and at 32 amps on an industrial socket on site at the weekend.
How much longer does charging take on a lower step?
Taking a 60 kWh battery from 20% to 80% needs roughly 36 kWh of energy. On a three-phase run that job takes about 1 hour 40 minutes at 32 amps, about 3 hours 15 minutes at 16 amps and about 5 hours 15 minutes at 10 amps; once losses are counted in, these times stretch somewhat. If you park the car overnight, a lower step costs you nothing in practice — the car is full again in the morning.
In short
- The current setting changes the current ceiling the unit reports to the car; it does not break charging, it slows it.
- You step down on weak runs, long extensions, shared sockets and unknown installations.
- The step should stay one notch below the fuse rating of the run.
- The real ceiling is set not by the unit but by whichever is lower, the capacity of the run or the car's AC charger.
- The Pro Mobile 2 offers six steps and can also be set from the app; Mini Mobile and Mono Mobile have two steps each.
Tell us the fuse rating of your run and the type of your socket; we will say which model and which step fit — straight from the manufacturer.
Request a QuoteFrequently Asked Questions
What is the current setting on a charger for?
In AC charging the current ceiling is set by the charger, not by the car; the unit keeps telling the car through a signal how many amps it may draw at most, and the car obeys that ceiling. The current setting lets you change it. That is how the same unit works both on a household socket with a weak fuse and on a three-phase industrial socket. Lowering the current does not break charging, it only slows it down — and on a weak or long run that is the right thing to do.
How many steps does the Pro Mobile 2 have and how are they set?
On the Pro Mobile 2 the charging current is set in six steps: 6, 10, 16, 20, 25 and 32 amps. The setting can be made in two places: from the mobile app or from the button on the unit. For comparison, Mini Mobile offers two steps at 10A/16A and Mono Mobile two steps at 16A/32A. Because six steps make fine adjustment to the capacity of the run possible, the Pro Mobile 2 can be used at home and on site with the same unit.
How many kW is 32 amps?
On a three-phase run 32 amps makes about 22.2 kW; it can move by a few hundred watts with the grid voltage. On the same run 25 amps gives about 17.3 kW, 20 amps about 13.9 kW, 16 amps about 11.1 kW, 10 amps about 6.9 kW and 6 amps about 4.2 kW. On a single-phase run the same current means roughly one third of the power: 16 amps makes 3.7 kW and 32 amps makes 7.4 kW.
Can an electric car be charged on weak wiring?
It can, but the current step has to be chosen for the capacity of the run. Charging is not a matter of minutes but a steady load lasting hours; that is why the number on the fuse is not taken as the current that can be drawn continuously. The practical rule is to stay one step below the fuse rating of the run: on a 16 amp run you pick the 10 amp step. Starting the first charge on a low step and checking the plug and cable by hand after half an hour is the most practical way to confirm it.
How much longer does charging take when you lower the current?
Taking a 60 kWh battery from 20% to 80% needs roughly 36 kWh. On a three-phase run that job takes about 1 hour 40 minutes at 32 amps, about 3 hours 15 minutes at 16 amps and about 5 hours 15 minutes at 10 amps; once losses are added the times stretch somewhat. For someone who parks the car overnight a lower step has no practical cost, because the car is full again in the morning.
If I pick the highest step, will the car always charge at that power?
No. The step on the unit only sets the upper limit; what actually applies is whichever is lower, the capacity of the run or the capacity of the car's own AC charger. A car whose onboard charger is 11 kW takes 11 kW even on a three-phase 32 amp socket. In the same way, connecting to a single-phase run never reaches three-phase power figures. That is why you should look at your car's AC charging power before raising the step.